The extraction check valve is the "last mechanical defense line" of the steam turbine extraction system, and its selection is directly related to the safety of the unit. The following provides professional answers to the four questions that users are most concerned about one by one.

Q1: Why is the extraction check valve called the "lifeline" of a steam turbine?

Answer: The reason why the steam extraction check valve is called the "lifeline" of the steam turbine is that it directly prevents the two major serious accidents of overspeed and water impact.

The steam extraction check valve is installed on the steam extraction pipelines of each stage of the steam turbine, close to the outlet of the steam extraction port. Its core function is like a "one-way door" : only allowing steam to flow from the steam turbine to the heater, and quickly and forcibly cutting off the reverse flow when necessary.

Prevent overspeed: When the unit suddenly drops the load, the high-pressure steam in the extraction pipe and the heater will flow back into the steam turbine in the opposite direction, driving the rotor to rotate continuously and causing the speed to soar. The steam extraction check valve closed rapidly at the moment of the accident, blocking the reverse flow path.

Prevent water impact: If the heater tube bundle breaks, water will flow back into the steam turbine along with the backflow steam. The high-temperature rotor will suddenly encounter cold water, generating huge thermal stress, which may cause the rotor to bend or even be scrapped. The exhaust check valve is also a key barrier to prevent such accidents.

W&T has been deeply engaged in the field of power station valves and offers a full range of steam extraction check valves that comply with ASME standards, including lift and swing structures, providing safe, reliable and fast-response protection for the steam extraction system of steam turbine units.

Q2: When selecting a steam extraction check valve, what technical parameters should be focused on?

Answer: When selecting a steam extraction check valve, the key parameters to focus on are the closing time, sealing grade, pressure and temperature grade, and flow resistance design.

1. Closing time: The industry generally requires that the time from receiving the signal to fully closing the valve be less than 0.5 seconds. It must be forced to drive by an external power system (pneumatic or hydraulic), rather than relying solely on medium reflux.

2. Sealing grade: After closing, it must achieve zero leakage or extremely low leakage, truly serving an isolation function. The sealing surface is usually surfacing with cobalt-based hard alloy, which is wear-resistant and ensures reliable sealing.

3. Pressure and temperature rating: According to the ASME standard, confirm the allowable working pressure of the valve at the corresponding temperature. The steam extraction system of power stations typically covers a range of 150LB to 4500LB, with a temperature range from -50℃ to 700℃.

4. Low flow resistance design: During normal operation, when the valve is fully open, the pressure drop of steam should be small to reduce energy loss and improve the efficiency of the unit.

Core parameters of Vittey air extraction check valve Diameter range: Forged 2" to 32", cast 2" to 64". Pressure rating: 150LB to 4500LB. Applicable temperature: carbon steel type -50℃ to 425℃, alloy steel type -50℃ to 640℃, stainless steel type -50℃ to 700℃. Quick closing time: less than 0.5 seconds. Sealing grade: API 598 VI.

Q3: What reliability guarantees are there in the structural design of the Viti steam extraction check valve?

The reliability guarantee of the Viti steam extraction check valve mainly focuses on five aspects: forced closing mechanism, hard alloy surfacing on the sealing surface, inclined valve seat design, movable valve disc structure and low flow resistance design.

1. Forced shut-off mechanism: The pneumatic/hydraulic actuator works in coordination with the counterweight. When the medium flows in the forward direction, the cylinder intake and the counterweight jointly keep the valve disc fully open. When the reverse flow signal is triggered, the cylinder depressurizes rapidly and the valve disc closes forcibly within 0.5 seconds.

2. Hard alloy surfacing on the sealing surface: The sealing surface is surfacing with cobalt-based hard alloy, which has excellent wear resistance and ensures stable and reliable sealing.

3. Inclined valve seat design: The sealing surface of the valve seat is inclined at a certain Angle to reduce the closing time, alleviate the impact, and protect the equipment.

4. Movable valve disc structure: The valve disc is movably connected to the rocker and can automatically align with the valve seat to ensure a precise fit of the sealing surface.

5. Low flow resistance design: The streamlined design of the valve body's inner cavity ensures a large flow capacity and low pressure loss during normal operation.

In terms of material configuration, the valve body is made of WCB, WC6, WC9, F91, and F92, the valve disc is made of 17-4PH precipitation-hardening steel, and the sealing surface is surfacing with Stellite alloy to ensure long-term reliability under high-temperature and high-pressure working conditions.

Q4: What are the typical achievements and qualification guarantees of Vitite exhaust check valves?

Answer: The Viti steam extraction check valve has been successfully applied in the heating renovation project of the 2×1000MW ultra-supercritical unit of Guoneng Lingwu, and has obtained the national A1-level TS license and TSG type test certificate.

In terms of performance: In the heating retrofit project of the 2×1000MW ultra-supercritical units at Guoneng Lingwu, the pneumatic check valves (with a closing time of ≤0.5 seconds) supplied by Vitai, in coordination with the electric shut-off valves and hydraulic quick-closing regulating valves, provided a complete valve solution from "control" to "protection" for the unit's steam extraction system.

In terms of qualifications: The Viti Russia factory has officially obtained the Special Equipment Production License (TS Certification) issued by the State Administration for Market Regulation, and at the same time, it has also obtained the Special Equipment Type Test Certificate (TSG Certification). In addition, Viti has obtained three international system certifications, namely ISO 9001, ISO 14001, and ISO 45001, as well as multiple qualifications such as CE certification, SIL certification, explosion-proof qualification certificate, ISO 15848 low emission certification, and API 607 fire protection certification.

Summary

The core logic for selecting a steam extraction check valve is as follows: First, clearly define the closing time, sealing grade, and pressure-temperature parameters; then, match the actuator and material; and finally, verify the supplier's TS/TSG qualifications and similar performance.

W&T, based on German technology, supported by Russian complete machine production, and guaranteed by A1-level TS/TSG qualifications, provides safe, reliable and fast-response protection for the steam turbine extraction system.



Submit requirements or feedback