faq
维替流体控制有限公司 2026-10-27 10:44 169
The desuperheating and pressure reducing device is the core equipment for converting high-temperature and high-pressure steam into the parameters required by users in cogeneration, centralized heating and industrial heating systems. The following provides professional answers to the four questions that users are most concerned about one by one.
Q1: What are the core components of a desuperheating and pressure reducing device?
The temperature and pressure reducing device consists of four parts: the pressure reducing system, the temperature reducing system, the safety protection device and the automatic control device.
1. Pressure reducing system: Through pressure reducing valves and throttling orifice plates, the pressure of the primary steam is reduced to the pressure required by the user by using multi-stage throttling technology.
2. Cooling system: Mechanical atomizing nozzles are used to spray water onto high-temperature steam to lower its temperature. The regulation of steam temperature is achieved by controlling the opening degree of the water spray desuperheater through the actuator. The desuperheater uses adjustable nozzles to achieve a good atomization effect.
3. Safety protection device: It is directly implemented by using an impulse safety device (consisting of a main safety valve and an impulse safety valve) or a spring safety valve. When the pressure of the secondary steam exceeds the set value, the overpressurized part of the steam is discharged to the atmosphere, thereby keeping the pressure of the secondary steam within the allowable range.
4. Automatic control device: It is used to control the steam pressure and temperature, keeping the pressure and temperature of the secondary steam within the required set values.
The W&T desuperheating and pressure reducing device adopts a desuperheating and pressure reducing valve structure, enabling steam desuperheating and pressure reducing to occur within the same valve and shortening the structural length. The adoption of single-seat water supply regulating valves or high-pressure differential water supply regulating valves can rationally distribute the pressure difference on the water supply system, and is suitable for medium-temperature and medium-pressure as well as sub-high-temperature and high-pressure parameters.
Q2: When selecting a temperature and pressure reducing device, what key parameters should be focused on?
Answer: The core of selecting a desuperheating and pressure reducing device should focus on three major dimensions: the parameters of the inlet/outlet steam, the number of pressure reduction stages, and the desuperheating method.
1. Pressure parameter matching: Clearly define the inlet pressure (P1) and outlet pressure (P2), and calculate the pressure difference (ΔP=P1-P2) to determine the number of pressure reduction stages. When ΔP≤3MPa, single-stage pressure reduction can meet the requirements. When ΔP>3MPa, multi-stage pressure reduction (usually 2-3 stages) should be adopted. By gradually reducing the pressure, the pressure load of each stage is decreased to reduce the erosion of the valve core and noise.
2. Temperature parameter matching: Clearly define the inlet temperature (T1) and outlet temperature (T2). The temperature difference determines the design of the desuperheating system. When ΔT≤100℃, simple jet cooling can be adopted. When ΔT>100℃, an enhanced atomization structure should be adopted to ensure that the desuperheating water is fully mixed and evaporated with the steam.
3. Flow rate and regulation ratio: The designed flow rate of the device should cover the maximum flow rate (Qmax) and the minimum flow rate (Qmin). Generally, the regulation ratio is required to be ≥10:1, and the outlet steam flow rate should be stably regulated within the rated range of 30% to 100%.
The main steam regulating valve of the Viti desuperheating and pressure reducing device has a diameter range of 1/2" to 30" (DN15-DN750), a pressure rating of CLASS 150 to CLASS 2500, and a temperature range of -29℃ to 550℃ The valve body materials include WCB, WCC, WC6, WC9, A105, F22, F91, CF8, CF8M, etc. The internal components are made of hard alloys such as 304+STL and 316+STL through surfacing welding.
Q3: What are the typical applications and achievements of the Vite desuperheating and pressure reducing device?
Answer: The Vite desuperheating and pressure reducing device has been widely applied in industries such as power, chemical engineering, and metallurgy, and has been successfully used in projects like Baishan Thermal Power Plant and Huaneng Haimen Power Plant.
The high regulation accuracy and large heat supply flow type desuperheating and pressure reducing device, which was tailor-made for the 2×300MW unit desulfurization flue gas waste heat recovery project of Weitai Baishan Thermal Power Co., LTD., has achieved safe and stable operation for nearly half a year continuously. The performance indicators of the equipment are excellent and have been highly recognized by the user. User feedback shows that this device performs outstandingly in core performance aspects such as the accuracy of pressure and temperature regulation and the heat recovery and utilization rate of waste heat.
In addition, Viti has also undertaken large-scale desuperheating and pressure reducing station projects such as Huaneng Haimen Power Plant. It takes steam from multiple sources including superheaters, reheating of cold and hot sections, and the middle exhaust, including two process packages: emergency gas source and main line gas source. The equipment integrates complete sets of devices such as pressure reducing valves, desuperheating water regulating valves, safety valves, and electric isolation valves to ensure the stability and reliability of the heating steam parameters.
Q4: What qualification guarantees does the Vite desuperheating and pressure reducing device have?
Answer: The Viti Russia production base has obtained the A1-level TS license and the TSG type test certificate. At the same time, it holds multiple qualifications including ISO three systems, CE, SIL, explosion-proof, ISO 15848, and API 607.
Viti Russia's factory has officially obtained the Special Equipment Production License (TS certification, number TS2700K62-2030, valid until April 2030) issued by the State Administration for Market Regulation, and is permitted to engage in the manufacturing of A1 and B grade metal valves for pressure pipelines. At the same time, obtain the Special Equipment Type Test Certificate (TSG certification).
In addition, Viti has obtained three international system certifications, namely ISO 9001, ISO 14001, and ISO 45001, as well as multiple qualifications such as CE certification, SIL certification, explosion-proof qualification certificate, ISO 15848 low emission certification, and API 607 fire protection certification.
Summary
The core logic for selecting a desuperheating and pressure reducing device is as follows: First, clearly define the parameters of the inlet/outlet steam (temperature, pressure, and flow rate), then determine the number of pressure reduction stages and the desuperheating scheme based on the pressure difference and temperature difference, and finally choose a professional brand with German technical background, Russian complete machine production qualifications, and similar project performance.
W&T, based on German technology, supported by Russian complete machine production, and guaranteed by A1-level TS/TSG qualifications, provides reliable temperature and pressure reducing device solutions for cogeneration and industrial heating systems.
Demand feedback