Self-controlled return valve (pump protection valve

Imported regulating valve

regulatingvalve

Current Location:Home > Product Center > Imported regulating valve > Main Text

Self-controlled return valve (pump protection valve

Thepumpprotectionvalveissetuptopreventoverload,overheatingandvaporizationfromcausingdamagetothewaterpumpwhenoperatingbelowtheminimumflowrate.Aslongasthepump'sflowrate...

Detailed Information


The pump protection valve is set up to prevent overload, overheating and vaporization from causing damage to the water pump when operating below the minimum flow rate. As long as the pump's flow rate drops below a certain value, the bypass return port of the valve will automatically open to ensure the minimum flow rate required by the pump.

维替自控回流阀,维替泵保护阀,保证泵最小流量

When a centrifugal pump is at a critical low load, a reliable recirculation system is required to prevent overheating. Many such systems are composed of several valves with different functions and require relatively high design, installation and maintenance costs. The automatic return valve can accurately and independently perform various functions in the circulation loop. This valve has excellent control performance and a long service life, and has been applied in the protection devices of feed water pumps in many thermal power plants and steel mills.

Working principle

The main valve of the automatic return valve is a check valve installed on the main pipeline. Besides the function of preventing the backflow of the medium, this valve also serves as a sensitive element and a power element, responsible for guiding the operation of the recirculation control valve. When the flow rate through the valve decreases, under the action of the spring force, the main valve disc moves towards the valve seat, driving the lever and triggering the pilot valve, thereby discharging the internal pressure of the piston head. The pressure acts on the corresponding piston, causing it to move and the bypass control valve to open. The liquid passes through multiple series elements and flows through a spiral groove with a continuous 90° turn to consume the destructive energy of high pressure, thereby controlling the flow rate and achieving the purpose of pressure reduction by consuming energy. As long as the pilot valve is open, the bypass valve also remains open. The main valve disc is in a position with low flow and no flow passing through. When the flow rate exceeds the minimum flow rate, the main valve disc opens and the pilot valve closes. The pressure entering the chamber acts on the piston through the annular gap around the pilot valve, controlling the valve to have a limited flow channel for the cooling liquid at low loads.

When the centrifugal pump is in normal working condition, the main valve disc of the automatic return valve is open, the pilot valve is closed, and the bypass control valve is closed. When the centrifugal pump is operating at a low load, the main valve disc of the automatic return valve is in the process of opening and closing, the pilot valve is partially open, and the bypass control valve is in the open state. When the centrifugal pump is in an unloaded state, the main valve of the automatic return valve is closed, the pilot valve is fully open, and the bypass control valve is open, passing through the minimum flow rate of full recirculation.

Technical parameters of the self-controlled return valve provided by Viti Fluid Control

Name Parameter
Valve diameter 1 1/4" to 24"
Pound class 150LB~2500LB
Material Forging: A105, WB36
Working temperature Forging: ≤425℃
Maximum pressure difference 400bar
Maximum bypass flow 50% of the main traffic



Submit requirements or feedback

Demand feedback