The self-controlled return valve (also known as the pump protection valve) is a key protective device for preventing overheating and vaporization of centrifugal pumps during low-load operation. The following provides professional answers to the four questions that users are most concerned about, in combination with the characteristics of the W&T self-controlled return valve.
Q1: What is the self-controlled return valve used for? Why does the pump system need it?
The core function of the self-controlled return valve is to prevent the centrifugal pump from overloading, overheating and vaporizing when operating at a flow rate lower than the minimum, thus ensuring the safety of the water pump.
When a centrifugal pump is at a critical low load, the flow rate is lower than the safety value, causing the water temperature inside the pump to rise and vaporize, which can lead to cavitation damage. The traditional solution requires the configuration of various valves with different functions, such as check valves, bypass control valves, multi-stage pressure reducing orifils, solenoid valves, and flow meters, to form a recirculation system. The design, installation and maintenance costs are all relatively high.
The W&T self-controlled return valve can accurately and independently perform various functions in the circulation loop. As long as the pump flow rate is lower than the set value, the bypass return port of the valve will automatically open to ensure the minimum flow rate required by the pump. This valve has excellent control performance and a long service life, and has been applied in the protection devices of feed water pumps in thermal power plants and steel mills.
Q2: What is the working principle of the Viti automatic control return valve?
Answer: The Viti automatic control return valve uses the main valve as the check valve installed on the main pipeline, which has the dual functions of preventing the backflow of the medium and guiding the operation of the recirculation control valve.
When the flow rate through the valve decreases, the main valve disc moves towards the valve seat under the action of the spring force, driving the lever and triggering the pilot valve, which releases the internal pressure of the piston head and opens the bypass control valve. The liquid passes through multiple series elements and flows through the spiral grooves with continuous 90° turns, consuming high-pressure destructive energy, controlling the flow rate and reducing pressure. As long as the pilot valve is open, the bypass valve also remains open.
Three operating states:
Normal working state: The main valve disc is open, the pilot valve is closed, and the bypass control valve is closed
Low-load working condition: The main valve disc is in the opening and closing process, the pilot valve is partially open, and the bypass control valve is in the open state
No-load state: The main valve is closed, the pilot valve is fully open, the bypass control valve is open, and the minimum flow rate through which all recirculation occurs
Q3: What are the technical parameters and installation requirements of the Viti automatic control return valve?
Answer: The technical parameters of the Viti self-controlled return valve cover diameters from 1¼" to 24" and pound grades from 150 lb to 2500LB. When installing, the main channel should be vertical and the medium should rise from bottom to top.
Technical parameters
Valve diameter: 1¼" to 24"
Pound class: 150LB to 2500LB
Material: Forged A105, WB36
Operating temperature: ≤425℃
Maximum pressure difference: 400bar
Bypass maximum flow rate: 50% of the main flow rate
Installation requirements: The valve should be installed as close as possible above the pump outlet. The main channel is in a vertical position, and the medium rises from bottom to top. The side passage is in a horizontal position. If the installation direction is different, it should be specified at the time of placing the order so that the spring force can be taken into consideration during the design.
Q4: In which industries and working conditions is the Viti automatic control return valve applicable?
Answer: The Viti self-controlled return valve is mainly applicable to the protection devices of feed water pumps in industries such as thermal power plants and steel mills, as well as the working conditions of centrifugal pumps that require reliable recirculation systems.
Typical application scenarios of self-controlled return valves include: protection of boiler feed water pumps in thermal power plants, protection of feed water pumps in steel mills, and recirculation systems of centrifugal pumps in chemical plants, etc. The common feature of these operating conditions is that when centrifugal pumps are running at low loads, a reliable recirculation system is required to prevent overheating. Traditional solutions need multiple valves to work in coordination, while the Viti automatic control return valve can complete multiple functions such as check, bypass, and pressure reduction with just one device, simplifying the system design and reducing installation and maintenance costs.
The W&T self-controlled return valve has been successfully applied in the feed water pump protection devices of many thermal power plants and steel mills.
Summary
The core logic for selecting an automatic return valve is as follows: First, determine the minimum flow rate and pressure difference of the pump, then confirm the valve diameter, pound grade and material, and finally check the installation direction and working condition compatibility.
W&T, based on Russian industrial technology and supported by Russian complete machine production, provides reliable automatic return valve solutions for the protection of feed water pumps in industries such as thermal power and steel.